Home
  • Home

 

Contact Information

Donald Hester
Washington State Licensed Home Inspector #647
WSDA#80050
InterNachi Member #NACHI10022401
509-670-9572

Contact Us

 

  • Home
  • About Me
  • Inspection Agreement- Clients
  • Blog
  • Contact Us
  • Foundation Certifications (order online)
  • Inspection Photo Gallery
  • Infrared Thermography
  • Links (businesses and resources)
  • Pricing
  • Sample Reports
  • What's Inspected
  • Building Code Questions
  • Washington State Standards of Practice
  • Qualifications
  • Areas Served
  • Sources
  • Product Recall Information and Resources
  • FAQ's
  • General Home Information
  • Homeowner Maintenace and Safety Guides
  • City/County/State Building Codes
  • Contractors
  • Reference Documents
  • Testimonials
  • "How To" Page
  • Credit Card Payment
 


site search by freefind advanced


 

NCW Home Inspections LLC
On Facebook

NCW Home Inspections LLC
1 plus if you like us

Tweet

 

 

                                Certified by the International Association of Certified Home Inspectors - Click here to verify.                               

 

  
Read Unbiased Consumer Reviews Online at AngiesList.com
Check our Home Inspection Reviews
on Angie's List

Home

DonHester's blog

A little BS on BX cables. Armored or Metal Clad Cables used in exterior installations.

Submitted by DonHester on Tue, 03/26/2013 - 11:51.

A little BS on BX cables.  Armored or Metal Clad Cables used in exterior installations.

 

Wenatchee and Chelan Real Estate Inspection Services.

 

Wiring in locations that are subject to “physical damage” will need protection. But what that protection is will depend on where the wires are installed and the environment of the installation.

 

As home inspectors we see a lot of wiring in locations that need protection. Many common areas I find unprotected wiring are in closets and cabinets.

 

But another very common area I find unprotected wiring during a home inspection is on the exterior of homes. Any wiring that is on the exterior of the home needs to be rated for use in damp or wet locations.

 

During a Chelan Home Inspection I came across the use of what is often called BX cable. BX is actually a brand name like Romex and Kleenex. BX is not defined as a term by the NEC and is technically called AC (armored cable).

Old BX Cable- AC Cable Wenatchee Real Estate

Armored cable was first listed with Underwriters Laboratories Inc. in 1899 for the Sprague Electric Co. of New York.  It was originally called “Greenfield Flexible Steel-Armored Conductors,” after one of its inventors, Harry Greenfield. Some will refer to this cable as Greenfield cable. Armored cable (AC) first appears in the 1903 NEC.

 

 

There were originally two initial versions of armored cable. One was called “AX” and the other “BX,” with the “X” standing for “experimental.”  The “BX” version became the one that eventually was produced, and hence the name “BX” became the common name.BX became the registered trade name of AC Cable distributed by General Electric who had acquired Sprague Electric.

 

So “BX” is defined as “AC” cable (armored clad) and “MC” is defined as Metal Clad cable. These two cable assemblies are very similar in construction. (See note on FMC below)

 

BX cables Type AC Cable Chelan Real Estate Inspection

 

The biggest difference between the two cable systems is that MC has full size ground wire while AC uses a combination of the jacket and a thin bonding strip or wire to function as the equipment ground. The bonding wire is unique to AC cable and this allows the outer metal armor in conjunction with the bonding wire to be used as an equipment ground.

 

Note: Early AC cable often does not have this bonding wire.

 

MC Cable with PVC coating Wenatchee Home Inspection

 

Now AC cable cannot be used in exterior or damp locations. Where MC Cable may be used in exterior applications but must be suitable for exterior or direct burial. This type of MC Cable will have a continuous PVC outer jacket.

 

Here are two examples from home inspections of AC/MC cables being used in exterior application that are not appropriate. As you can see they do not have a protective PVC outer jacket that would allow the use on exterior applications.

 

Buried BX cable Wenatchee Home Inspection BX or MC cable not rated for exterior use Chelan Real Estate Inspections

 

Knowing when and where a type of cabling system can and cannot be used is very important in electrical installations and is often a mark that a professional has not done the work.

Note: There is also FMC, (flexable metal conduit) called by the slang of "Greenfield" that comes without conductors installed.

 

“If you think it's expensive to hire a professional to do the job, wait until you hire an amateur.”

Red Adair

 

NCW Home Inspections, LLC  is a Licensed Washington State Home Inspection service located in Wenatchee Washington serving Chelan County, Douglas County, Kittitas County, Okanogan County and Grant County Washington and the cities of Wenatchee, Leavenworth, Cashmere, Oroville, Cle Elum, East Wenatchee, Quincy and many more…  

 

Your Wenatchee and Chelan Professional Real Estate, Home and Structural Pest Inspection Service

 

www.ncwhomeinspections.com                                               509-670-9572

« first‹ previous…253254255256257258259260261…next ›last »
Syndicate content

NCW Home Inspections, LLC Serving Chelan, Douglas, Okanogan, Kittitas and Grant Counties.
copyright North Central Washington Home Inspections, LLC 2016

ncwhomeinspections@gmail.com



Website hosted by Home Inspector Pro Home Inspection Software - Admin Login