Home
  • Home

 

Contact Information

Donald Hester
Washington State Licensed Home Inspector #647
WSDA#80050
InterNachi Member #NACHI10022401
509-670-9572

Contact Us

 

  • Home
  • About Me
  • Inspection Agreement- Clients
  • Blog
  • Contact Us
  • Foundation Certifications (order online)
  • Inspection Photo Gallery
  • Infrared Thermography
  • Links (businesses and resources)
  • Pricing
  • Sample Reports
  • What's Inspected
  • Building Code Questions
  • Washington State Standards of Practice
  • Qualifications
  • Areas Served
  • Sources
  • Product Recall Information and Resources
  • FAQ's
  • General Home Information
  • Homeowner Maintenace and Safety Guides
  • City/County/State Building Codes
  • Contractors
  • Reference Documents
  • Testimonials
  • "How To" Page
  • Credit Card Payment
 


site search by freefind advanced


 

NCW Home Inspections LLC
On Facebook

NCW Home Inspections LLC
1 plus if you like us

Tweet

 

 

                                Certified by the International Association of Certified Home Inspectors - Click here to verify.                               

 

  
Read Unbiased Consumer Reviews Online at AngiesList.com
Check our Home Inspection Reviews
on Angie's List

Home

DonHester's blog

How do you know? Energy Compliance-Washington State Energy Code

Submitted by DonHester on Sat, 12/23/2017 - 11:33.


How do you know? Energy Compliance-Washington State Energy Code

Wenatchee Home Inspections




New construction requires builders to hit some energy efficiency marks, or as the code state credits. The amount of credits you will need to achieve will be based on the size of the home.



                           


Here is the the credits required based on size-

1. Small Dwelling Unit: 1.5 credits

Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square

feet of fenestration area. Additions to existing building greater than 500 square feet of heated

floor area but less than 1500 square feet.

2. Medium Dwelling Unit: 3.5 credits

All dwelling units that are not included in #1 or #3.

Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits.

3. Large Dwelling Unit: 4.5 credits

Dwelling units exceeding 5000 square feet of conditioned floor area.

Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits.

4. Additions less than 500 square feet: 0.5 credits



The energy code gives you several ways to achieve these credits typically made up of several approaches such as “HIGH EFFICIENCY HVAC EQUIPMENT 3b: Air-source heat pump with minimum HSPF of 9.0” this will give you 1.0 credits or “EFFICIENT WATER HEATING 5c: Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Northern Climate Specifications for Heat Pump Water Heaters” this earns you 1.5 credits.


(Here is a list of the credits you can achieve- http://www.energy.wsu.edu/Documents/Table_406.2_2015_Energy_Credits.pdf )



So if you are inspecting new construction and looking to evaluate some of these components you need some information to make observations. This information comes in the form of an “Energy Compliance Certificate”. This is to be filled out by the builder or design professional. This is a required on all new homes and goes back a few code cycles.



                                



2015 IRC-

R401.3 Certificate


A permanent certificate shall be completed and posted on or within three feet of the electrical distribution panel by the builder or registered design professional. The certificate shall be completed by the builder or registered design professional. The certificate must list the energy features of the structure.


Checklist and Certification-

http://www.energy.wsu.edu/Documents/2015_Prescriptive_Checklist.pdf


http://www.energy.wsu.edu/Documents/WSEC-2015-Avery-6573_2_Per_Sheet.pdf


One problem I am running into on new construction is that these certificates are not being completed (Example below). Thus I am not able to always know what some of the energy requirements are required. This may be particularly good to know when looking at insulation, does the house require R-38 or R-49 insulation in the attic, or R-30 vs R-38 insulation in crawlspaces?



                     
                                   (Names erased to protect the not so innocent)



So when buying a new home or if performing a home inspection on new construction I would recommend verifying that the energy compliance certificate is present and complete.





You can only teach someone, as much as they are willing to learn."

Chris G. Varona

 


If you find any errors or have additional information that would expand on any code, building standards or manufacturer requirements please let me know.



NCW Home Inspections, LLC  is a Licensed Washington State Home Inspection service located in Wenatchee Washington serving Chelan County, Douglas County, Kittitas County, Okanogan County and Grant County Washington and the cities of Wenatchee, Leavenworth, Cashmere, Oroville, Cle Elum, East Wenatchee, Quincy and many more…  

Your Wenatchee and Chelan Professional Real Estate, Home and Structural Pest Inspection Service

Instructor- Fundamentals of Home Inspection-  Bellingham Technical College

WA Home Inspector Advisory Licensing Board

www.ncwhomeinspections.com                                                   509-670-9572

You can follow me on Facebook, Twitter, Google+ and on my website Blog.

                      

« first‹ previous…505152535455565758…next ›last »
Syndicate content

NCW Home Inspections, LLC Serving Chelan, Douglas, Okanogan, Kittitas and Grant Counties.
copyright North Central Washington Home Inspections, LLC 2016

ncwhomeinspections@gmail.com



Website hosted by Home Inspector Pro Home Inspection Software - Admin Login